5.3.4Open-Flame Gas Appliances (including Gas Refrigerators) .1Appliances must not be positioned close to engines and fuel tanks. Selection of open-flame

cooking appliances must have due regard to the fire risk involved. The type of equipment should be suitable for marine duty, and manufacturers’ fitting and operating instructions must be carefully followed. .2All types of stoves and heating appliances must be strongly secured to the surrounding structure.

New appliances must conform to the requirements of Regulation (EU) 2016/426 and Marine Notice No. 37 of 2017 – “Use of liquefied petroleum gas (LPG) installations and systems on merchant vessels, fishing vessels, pleasure craft and other marine craft”. .3In any compartment containing a gas-consuming appliance, safe means for detecting any leakage

of gas must be provided, or in any adjoining space or compartment into which the gas may seep. Detectors must be fitted in each compartment in accordance with fitting instructions. The alarm unit, which should incorporate an audible and visible alarm, and the control panel should be fitted outside the space containing the installation. In all cases, arrangements must be such that the detection system can be tested frequently while the vessel is in service. .4Liquefied petroleum gas (L.P.G.) systems must comply with Marine Notice No. 37 of 2017. It

should be noted that the Marine Notice also contains maintenance and servicing requirements.