4.2.4 Bilge Pumping Systems
4.2.4Bilge Pumping Systems .1All vessels are to have a bilge pumping system in accordance with Acceptable Construction Rules.
The number and capacity of bilge pumps are to be a minimum of those required for pre-2004 vessels. Bilge piping minimum diameters are to be as follows:
Bilge main, vessels of Loa ≥ 7 m - 35 mm inside diameter Bilge main, vessels of Loa < 7 m - 30 mm inside diameter Branch bilge pipes, all vessels - 30 mm inside diameter .2In vessels where the engine is enclosed under the deck, or in open boats, where the bilge space
cannot be readily seen, an audible and visual level alarm is to be fitted, with indication at the helm or control position.