4.2.1Machinery .1The layout of engine rooms and propulsion machinery must satisfy the following, and the

requirements of Acceptable Construction Rules:

a.Access to be arranged clear of moving parts and heated surfaces. b.Exposed moving parts such as shafts, pulleys and belts to be fitted with guards. c.Access ladders are to be of metal. d.Floor plates are to be non-slip and securely fastened with accessible fasteners. e.Lighting to be weathertight and vibration proof.

f.Ventilators are to be designed to prevent build-up of excessive heat. g.Valves and fittings in piping systems to be clearly marked with function. h.Ease of access is to be provided for all servicing operations. i. Enclosed engine rooms in vessels of Loa ≥ 7m must be provided with an alternative means of escape to the open deck. j. On decked vessels, with enclosed engine rooms, fuel supply mains are to be capable of being closed from outside the engine room, by means of wire or rod operated valves. .2Propulsion engines are to be designed for use with fuel oil having a flash point greater than 60°C.

Petrol-driven engines will be acceptable only when mounted as outboards on transoms. .3All engines are to be provided with efficient means of control and are to be capable of being

started from a dead ship condition.

.4Inboard engines in open boats must be fitted with a weathertight cover or box.

.5It is recommended that outboard engines be fitted with a kill switch and extendable cord and

connected when vessel is underway.