2.1.17Air Pipes .1Air pipe arrangements will be accepted subject to the following provisions:

a)Air pipes must be of sound construction and operate efficiently. b)Air pipe tops without a proprietary closing device or fitting, must be fitted with collapsible

hose or other effective means of closure. c)Provision should be made to prevent a vacuum forming in the pipe or tank. d)Exposed air pipes, in excess of 25mm diameter, serving fuel oil, hydraulic oil, and

lubricating oil tanks must be fitted with anti-flash gauze diaphragms.

2.1.18Sea Inlets and Discharges .1Sea inlets and discharges should be fitted with an efficient means of closure. The openings of the

inlets and discharges should be fitted with a valve or seacock at the hull connection, which is readily accessible for operation in an emergency. If such valves are inaccessible in an emergency,

they should be fitted with a remote means of operation, i.e. by extended spindle or wire pull device. .2Where sea inlet piping systems comprise flexible hose, the connection of the hose to the sea inlet

must be of sound and efficient construction.

.3Openings serving as discharges from engine cooling water, bilge and general service pumps, galley

and toilet drains, etc., should be also fitted with an automatic non-return valve adjacent to the closing valve. Alternatively, a screw down non-return type valve may be fitted.

Pages 19–20 · View in original PDF